Sentinel Pro has a unique and modern design and improved performance developed by the Riello UPS research and development team. Sentinel Pro uses on-line double conversion technology, resulting in the highest levels of reliability and maximum protection for critical loads such as server. IT, and voice/data applications. For business continuity applications requiring long battery runtimes, battery autonomy can be extended up to several hours using ER models fitted with more powerful battery charges. The front display panel has been entirely redesigned, adding an LCD display that shows the input and output voltages, battery readings and UPS operating status information. The Inverter and the microprocessor control stage has been completely redesigned to provide increased efficiency and greater configuration options. Maximum expandibility: the Sentinel Pro is supplied as standard with a USB port and an expansion slot for protocol conversion or relay contacts boards.
Available in 1:1 singlephase/singlephase 700-3000 VA.
For SOHO, E-Medical, Industry, Emergency.
Riello UPS All Rights Reserved.
Technical Specification
MODELS | SEP 700 | SEP 1000 | SEP 1000ER | SEP 1500 | SEP 2200 | SEP 2200ER | SEP 3000 | SEP 3000 ER |
POWER | 700 VA/560 W | 1000 VA/800 W | 1500 VA/1200 W | 2200 VA/1760 W | 3000 VA/2400 W | |||
INPUT | ||||||||
Nominal voltage | 220-230-240 Vac | |||||||
Voltage range without battery intervention | 140 Vac < Vin < 276@50% LOAD/184 Vac<Vin<276 Vac @100% LOAD | |||||||
Maximum permitted voltage | 300 Vac | |||||||
Nominal frequency | 50/60 Hz | |||||||
Frequency range | 50 Hz ± 5%/60 Hz ± 5% | |||||||
Power factor | > 0,99 | |||||||
Current distortion | ≤ 7% | |||||||
BYPASS | ||||||||
Voltage tolerance | 180-264 Vac | |||||||
Frequency tolerance | Frequency selected (from ±1,5 Hz to ±5Hz configurable) | |||||||
Overload Times | 125% for 5 seconds, 150% for 1 second | |||||||
OUTPUT | ||||||||
Voltage distortion with linear load/with non-linear | <2% / <4% | |||||||
Frequency | Selectable: 50 Hz or 60 Hz or self-learning | |||||||
Static variation | ±1% | |||||||
Dynamic variation | ≤5% in 20 msec. | |||||||
Waveform | Sinusoidal | |||||||
Current crest factor | 3:1 | |||||||
Efficiency ECO and Smart Active Modes | 98% | |||||||
BATTERIES | ||||||||
Type | VRLA AGM maintenance-free lead based; Supercaps | |||||||
Recharge Time | 2-4 hours | N.A. | 2-4 hours | N.A. | 2-4 hours | N.A. | ||
OTHER FEATURES | ||||||||
Net Weight (kg) | 10,9 | 13,3 | 7 | 14,8 | 25,6 | 14 | 28 | 15 |
Gross Weight(kg) | 12,5 | 14,9 | 8,6 | 15,5 | 28,8 | 17 | 31,2 | 18 |
Dimensions (wxDxH)(mm) | 158 x 422 x 235 | 325 x 446 x 333 | ||||||
Packaging dimensions (WxDxH)(mm) | 245 x 500 x 340 | 325 x 585 x 470 | ||||||
Protection against overvoltage | 300 joules | |||||||
Protections | Overcurrent-short-circuit-overvoltage-undervoltage-temperature-excessive low battery | |||||||
Communications | USB/DB9 with RS232 and contacts/Slot for communication interface | |||||||
Input plugs | 1 IEC 320 C14 | 1 IEC 320 C20 | ||||||
Output Sockets | 4 IEC 320 C13 | 8 IEC 320 C13 | 8 IEC 320 C13+1IEC 320 C19 | |||||
Standards | Safety: EN 62040-1 and Directive 2006/95/EL;EMC:EN 620040-2 category C2 and Directives 2004/108/EL | |||||||
Operating temperature | 0°C/+40°C | |||||||
Relative humidity | <95% non-condensing | |||||||
Colour | Black | |||||||
Noise level at 1m (ECO MODE) | <40 dBA | |||||||
Standard equipment provided | Power cable-IEC-IEC cable, USB cable, safety manual, quick start guide |
Sentinel Power Green is the ideal solution for protecting IT systems, telecommunications equipment and mission critical systems such as safety devices, ensuring maximum power reliability. Sentinel Power Green is designed and built using state-of-the-art technology and components to provide maximum protection to the powered loads with no impact on downstream systems and optimized energy savings. The series includes 6 kVA single/singlephase and 8-20 kVA single/single-phase models with on-line double conversion technology (VFI): the load is powered continuously by the inverter which supplies a sinusoidal voltage, filtered and stabilized in terms of form and frequency. Input and output filters provide significant further immunity from mains disturbances and lightning strikes. In terms of technology and performance, Sentinel Power Green is one of the best UPS available on the market today: selectable Economy Mode and Smart Active Mode functions; custom diagnostics LCD display, RS232 and USB interfaces with Powershield software, ESD input, interface slot with optional boards.
Available in 1:1 singlephase/singlephase 6 kVA and 1:1/1:3 8-20 kVA.
For SOHO, Datacentre, E-Medical, Industry, Transport, Emergency.
Riello UPS All Rights Reserved.
Technical Specification
MODELS | SPM 6 | SPH 8 | SPH 10 | SPH 10 ER | SPH 15 | SPH 20 | SPH 20 ER |
POWER | 6000 VA/5400W | 8000/6400W | 10000VA/9000W | 15000VA/13500W | 20000VA/18000W | 20000VA/18000W | |
INPUT | |||||||
Nominal voltage | 220-230-240 Vac 1 ph | 220-230-240 Vac 1 ph/380-400-415 Vac 3 ph +N | |||||
Voltage range without battery intervention | 176 Vac@100% load/110 Vac @50% load | ||||||
Maximum permitted voltage | 276 Vac | ||||||
Nominal frequency | 50/60 Hz±10 Hz | ||||||
BYPASS | |||||||
Voltage tolerance | 160-276 Vac (selectable in Economy Mode or Smart Active Mode | ||||||
Frequency tolerance | selected frequency ±10% | ||||||
Overload Times | 125% for 1 min, 150% for 10 seconds | ||||||
OUTPUT | |||||||
Nominal Voltage | 220-230-240 Vac selectable | ||||||
voltage distortion | <2% with linear load/ <5% with non-linear load | ||||||
Current distortion | 3% | ||||||
Frequency | 50/60 Hz selectable or with automatic selection | ||||||
Static variation | ±1,5% | ||||||
Dynamic variation | ≤5% in 20 ms | ||||||
Waveform | Sinusoidal | ||||||
Crest factor | ≥3: 1 | ||||||
BATTERIES | |||||||
Type | VRLA AGM maintenance-free load based | ||||||
Recharge Time | 6-8 hours | ||||||
Recharge current(only for ER versions) | N.A. | 8 A | N.A | 8 A | |||
OTHER FEATURES | |||||||
Net Weight (kg) | 63 | 78 | 84 | 28 | 146 | 157 | 48 |
Gross Weight(kg) | 77 | 92 | 98 | 42 | 164 | 175 | 66 |
Dimensions (wxDxH)(mm) | 262 x 654 x 708 | 350 x 731 x 818 | |||||
Packaging dimensions (WxDxH)(mm) | 720 x 428 x 970 | 870 x 475 x 1075 | |||||
Smart Active Efficiency | up to 98% | ||||||
Protections | overcurrent-short-circuit-overvoltage-undervoltage-temperature-excessive low battery | ||||||
Communications | USB/ RS232 + slot forr communication interface | ||||||
Parallel | max.2 units in parallel with optional kit | ||||||
Input plugs | terminal block | ||||||
Output sockets | Terminal block + 2 IEC 320 C13 | ||||||
Standards | EN 62040-1 EMC EN 62040-2 Directives 2006/95/EC- 2004 /108 EC EN 62040-3 | ||||||
Operating temperature | 0°/+40°C | ||||||
Relative humidity | <95% non-condensing | ||||||
Colour | Dark grey RAL 7016 | ||||||
Noise level at 1 m (ECO Mode) | <40 dBA | ||||||
Moving the UPS | castors |
Sentinel Power is the ideal solution for powering sensitive, mission critical systems such as safety devices (electro-medical devices), ensuring maximum power reliability. The series includes 5-6 kVA single/singlephase and 6,5-8-10 kVA single/singelphase and three/singlephase models with on-line double conversion technology (VFI): the load is powered continuously by the inverter which supplies a sinusoidal voltage, filtered and stabilized in terms of voltage, form, and frequency. Input and output filters provide significant further immunity from mains disturbances and lightning strikes. In terms of technology, performance (selectable Economy and Smart Active Modes) and diagnostics (LCD custom display, RS232 and USB interfaces with Powershield 3 software included, ESD input, interface slot for optional boards), Sentinel Power is one of the best UPS available on the market.
Available in 1:1 singlephase/singlephase 5-6 kVA, 1:1 singlephase/singlephase 3:1 threephase/singlephase 6,5-10kVA.
For SOHO, Datacentre, E-Medical, Industry, Transport, Emergency.
Riello UPS All Rights Reserved.
Technical Specification
MODELS | SPW 5000 | SPW 6000 | SPT 6500 | SPT 8000 | SPT 10000 |
POWER | 5000 VA/ 4000 W | 6000VA/4800W | 6500 VA/ 5200 W | 8000 VA/ 6400W | 10000VA/8000W |
INPUT | |||||
Nominal voltage | 220-230-240 Vac single-phase | 220-230-240 Vac single-phase or 380-400-415 Vac Three-phase +N | |||
Voltage range without battery intervention | 170 Vac@ 100% load/140 Vac @50% load | ||||
Nominal frequency | 50/60 Hz ±5Hz | ||||
BYPASS | |||||
Voltage tolerance | 180-264 Vac (selectable in Economy Mode or Smart Mode Active Mode) | ||||
Frequency tolerance | selected frequency ±5% | ||||
Overload Times | 125% for 4 seconds, 150% for 0,5 seconds | ||||
OUTPUT | |||||
Nominal Voltage | 220-230-240 Vac selectable | ||||
voltage distortion | <3% with linear load/<6% with non-linear load | ||||
Frequency | 50/60 Hz selectable or with automatic selection | ||||
Static variation | ±1,5% | ||||
Dynamic variation | ≤5% in 20 ms | ||||
Waveform | Sinusoidal | ||||
Crest factor | ≥3:1 | ||||
BATTERIES | |||||
Type | VRLA AGM maintenance-free load based | ||||
Recharge Time | 6-8 hours | ||||
OTHER FEATURES | |||||
Net Weight (kg) | 91 | 92 | 105 | 106 | |
Gross Weight(kg) | 99 | 100 | 110 | 111 | |
Dimensions (wxDxH)(mm) | 282 x 785 x 615 | ||||
Packaging dimensions (WxDxH)(mm) | 863 x 388 x (650 +15) | ||||
Smart Active Efficiency | up to 98% | ||||
Protections | Overcurrent-short-circuit-overvoltage-undervoltage-temperature-excessive low battery | ||||
Communications | USB/ RS232 + slot for communications interface | ||||
Input plugs | Terminal board | ||||
Output sockets | Terminal board + 2 IEC 320 C13 | ||||
Standards | EN 62040-1 EMC EN 62040-2 Directives 2006/95/EC-2004/108 EC EN 62040-3 | ||||
Operating temperature | 0°C/+40°C | ||||
Relative humidity | <95% non-condensing | ||||
Colour | Dark grey RAL 7016 | ||||
Noise level at 1m (ECO Mode) | <45 dBA | ||||
Moving The UPS | castors |
The Multi Sentry series is ideal for protecting data centres and telecommunications systems, IT networks and critical system in general, where the risks connected with poor energy supply can compromise the continuity of activities and services. The Multi Sentry series is available in 30-40-60-80-125-160-200 kVA models with three-phase input and output and on-line double conversion technology in accordance with VFI-SS-111 classification (as set out in standard IEC EN 62040-3). Multi Sentry is designed and built using state-of-the-art technology and components. It has a fully controlled IGBT rectifier to minimize the impact on the grid. It is controlled by a DSP (Digital Signal Processor) microprocessor, to provide maximum protection to the powered loads with no impact on downstream systems, and optimized energy savings.
Available in 3:3 threephase/threephase 30-200 kVA.
For Datacentre, E-Medical, Industry, Transport, Emergency.
Riello UPS ALl Rights Reserved.
Technical Specification
MODELS | MST 30 BAT | MST 40 BAT | MST 60 | MST 80 | MST 100 | MST 125 | MST 160 | MST 200 |
Nominal Voltage | 380-400-415 Vac three-phase + N | |||||||
Nominal Frequency | 50/60 Hz | |||||||
Frequency Tolerance | 40-72 Hz | |||||||
Power Factor at full load | 0,99 | |||||||
Current distortion | THDI≤3% | THDI≤2,5% | ||||||
BYPASS | ||||||||
Nominal Voltage | 380-400-415 Vac three-phase + N | |||||||
Number of phases | 3+N | |||||||
Voltage tolerance (ph-N) | 180-264 V (selectable) | |||||||
Nominal frequency | 50 or 60 Hz (selectable) | |||||||
Frequency tolerance | ±5(selectable) | |||||||
Bypass overload | 125% for 60 minutes, 150% for 10 minutes | |||||||
OUTPUT | ||||||||
Nominal power (kVA) | 30 | 40 | 60 | 80 | 100 | 125 | 160 | 200 |
Active power (kW) | 27 | 36 | 54 | 72 | 90 | 112,5 | 160 | 200 |
Power factor | 0,9 | 1 | ||||||
Number of phases | 3+N | |||||||
Nominal voltage | 380-400-415 Vac three-phase + N(selectable) | |||||||
Static variation | ±1% | |||||||
Dynamic variation | ±3% | |||||||
Crest factor | 3:1 lpeak/lrms | |||||||
Voltage dsitortion | ≤1% with linear load/≤3% with non-linear load | |||||||
Frequency | 50/60 Hz | |||||||
Frequency stability during battery operation | 0,01% | |||||||
BATTERIES | ||||||||
Type | VRLA AGM/GEL/NiCd/Li-ion/Supercaps | |||||||
Recharge time | 6 hours | |||||||
INFO FOR INSTALLATION | ||||||||
Weight without batteries(kg) (MCT/MST) | 135 | 145 | 190 | 200 | 220 | 250 | 450 | 460 |
Dimensions (WxDxH)(mm) | 440 x 850 x 1320 | 500 x 800 x 1600 | 650 x 840 x 1600 | 850 x 1050 x 1900 | ||||
Communications | 3 slots for communications interface/USB/RS232 | |||||||
Operating temperature | 0 °C/+40°C | |||||||
Relative humidity | 90% non-condensing | |||||||
Colour | Dark Grey RAL 7016 | |||||||
Noise level at 1m [dBA±2](Smart Active) | < 40 dBA | < 63 dBA | < 50 dBA | |||||
IP Rating | IP20 | |||||||
Smart Active efficiency | up to 99% | |||||||
Standards | European Directives: L V2006/95/CE low voltage Directive | |||||||
EMC 2004/108/CE electromagnetic compatibility Directive | ||||||||
Standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2C2 | ||||||||
Classification in accordance with IEC 62040-3(Voltage Frequency Independent) VFI-SS-111 | ||||||||
Moving the UPS | castors (30-200 kVA) |
The Riello MULTI POWER (MPW) is the ultimate modular UPS for DATA CENTERS and other critical LOADs. The MULTI POWER is designed to protect any critical high-density computer and IT environment., whilst achieving maximum availability. The MPW grows along with the demands of the business without over-sizing the UPS- optimizing both the initial investment and the Total Cost of Ownership. As soon as demand increases, the Riello MPW modular solution can expand its power capability, maintaining the highest levels of power protection, availability, redundancy, and investment savings. Digital technology has an increasingly strong influence on day-to-day activities in almost all sectors and applications such as healthcare, power generation, social networking, telecommunications, commerce, and education. Subsequently, any activities and equipment related to data storage, processing and transfer should be supplied from the most reliable power source. Multi Power ensures that a scalable, secure, high quality power supply is available for a variety of critical load applications. The new MPW Power Modules feature the very latest in UPS technology. With its three level Neutral Point Clamped (NPC) inverter and Power Factor Corrected (PFC) input control, the MPW ensures the highest level of performance in terms of overall efficiency, input power factor and harmonic impact on the supply source.
Available in 3:3 threephase/threephase 1-28 x 42 kW up to 1 MW + redundancy
For Datacentre, Transport.
Riello UPS All Rights Reserved.
Technical Specification
MODELS | MPW-from 42 to 294 kW1 | ||||
Voltage[V] | 380-400-415 Vac Three-Phase plus neutral | ||||
Voltage tolerance[V] | 240 to 4802 | ||||
Frequency tolerance [Hz] | 40 to 72 | ||||
Power factor | 1 | ||||
THDI[%] | <3,5 | ||||
BYPASS | |||||
Nominal power[W] | 252 (Power Cabinet)/ 126 (Combo cabinet) | ||||
Nominal voltage [V] | 380-400-415 Vac Three-Phase plus neutral | ||||
Voltage tolerance [V] | from 180 (adjustable 180-200) to 264 (adjustable 250-264) referring to Neutral | ||||
Nominal frequency [Hz] | 50 or 60 | ||||
Overload | 125% for 10 minutes; 150% for 1 minute | ||||
BATTERIES | |||||
Layout | Modular type made up by Battery Unit (named BU) or Free Standing Battery Box/ Shelf | ||||
Battery Unit Features | VRLA batteries line up Constant voltage and current measuring Battery status monitoring via MPW LCD display | ||||
Nominal voltage[V] | 380/400/415 Vac Three-Phase plus neutral | ||||
Nominal frequency [Hz] | 50 or 60 | ||||
Voltage stability [%] | ±0,5 | ||||
Dynamic stability | EN62040-3 class performance 1 distorting load | ||||
OVERALL SPECIFICATION | |||||
Power Module nominal power[kW](Named PM) | 42 | ||||
Output power factor [pf] | 1 | ||||
Eco Mode Efficiency | up to 99% | ||||
Cabinet Type | Power Cabinet | Combo Cabinet | Battery Cabinet | ||
Nominal Power [kW] | 294 | 126 | N.A. | ||
Parallelable (up to) | 4 | 4 | N.A. | ||
Cabinet lay out description | 7 x PM3 | 3xPM3 | 9x Battery Shelves | ||
5 x battery shelves | |||||
Dimensions [WxDxH] | 600 x 1050 x 2000 | 600 x 1050 x 2000 | 600 x 1050 x 2000 | ||
Weight[kg] (without PM3 /BU 4) | 320 | 360 | 280 | ||
System Noise level at 1m[dBA±2](SmartActive) | <68 | <65 | N.A. | ||
Cabinet IP rating | IP20 finger proof (either with cabinet doors open or closed) | ||||
Cable input | Rear side either top or bottom | ||||
Color | RAL 9005 | ||||
Standards | Safety:IEC EN62040-1 EMC;IEC EN 62040-2-category C2 | ||||
Moving cabinet types UPS | Castors (any cabinet type is shipped without PM and BU) |
NOTE: All performances quoted in a single row refer to any UPS system configuration from one to seven modules running in parallel unless specified differently.
1 Including Redundancy
2 Conditions applied
3 PM = Power Module (42 kW)
4 BU = Battery Unit1 Including Redundancy
The Multi Guard modular UPS is scalable three-phase/three-phase uninterruptible power supply system with double conversion technology. Its power capacity ranges from 15 kVA to 120kVA, delivering the best combination of reliability, functionality and flexibility. The Multu Guard N+X parallel architecture adopts a highly intelligent modular design to achieve maximum power availability and redundancy. It is specially designed to meet the protection demands of mission critical loads in data centres or other important applications. Each module has an individual power capacity of 15 kVA, and a standard cabinet can be fitted with up to 8 modules to reach 120 kVA. If the load is within permitted limits, modules can be hot-swapped to enable true power contiuity without any interruptions.
System Features
- Maximum 120 kVA capacity in 19” rack.
- Input power factor >0,99 THDi <2% and output voltage distortion equal to 1,5%.
- 15 kVA per module with hot-swap function.
- The LCD display on the front panel displays unit status and important information such as input and output nominal values, capacity, temperature, and autonomy.
- Communication port for standard Ethernet and relay contact board.
- DSP technology, IGBT input.
- 36 Ampere battery charge current on a 120 kVA system.
Available in 3:3 threephase/threephase 1-8 x 15 kVA.
For Datacentre, E-Medical.
Riello UPS All Rights Reserved.
Technical Specification
MODELS | GMT-from 15 kVA to 120 kVA | |||
INPUT | ||||
Voltage | 380-400-415 Vac, three-phase + N | |||
Voltage tolerance | from 294 Vac to 520 Vac | |||
Frequency tolerance | between 40 Hz and 70 Hz | |||
Power factor | >0,99 | |||
THDi | <2% | |||
BYPASS | ||||
Voltage | 380-400-415 Vac, three-phase + N | |||
Voltage tolerance | from 323 Vac to 437 Vac | |||
Transfer time from on-line to off-line or viceversa | 0 Sec | |||
OUTPUT | ||||
Voltage | 380-400-415 Vac, three-phase + N (selectable) | |||
Voltage stability | ≤1,5 % | |||
Frequency | 50 Hz/ 60 Hz | |||
UPS MODULE | ||||
Power | 15 kVA/ 13,5 kW | |||
Output Power | 15 kVA x number of modules, up to maximum of 8 | |||
SPECIFICATION | ||||
Noise level at 1m (ECO Mode) | from ≤60 dBA to ≤ 62 dBA | |||
Operating temperature | 0°C /+40°C | |||
Humidity | 20%-90% non-condensing | |||
Storage temperature | -15°C + 55°C | |||
UPS module weight (kg) | 35 | |||
UPS module dimensions (WxDxH)(mm) | 440 x 700 x131 | |||
GMT 30 cabinet dimensions (WxDxH)(mm) | 600 x 1000 x 1500 | |||
GMT 60 cabinet dimensions (WxDxH)(mm) | 600 x 1000 x 2000 | |||
GMT 120 cabinet dimensions (WxDxH)(mm) | 600 x 1000 x 2000 | |||
Modular battery cabinet dimensions (WxDxH)(mm) | 9 battery shelves, 36 battery modules 597 x 1003 x 2000 | |||
Eco Mode efficiency | up to 99% | |||
Standards | Safety: IEC 62040-1 EMC: IEC 62040-2 | |||
Moving the UPS | transpallet |
Total Protection
Master MPS series UPS provide maximum protection and power quality for mission critical loads, including data centres, industrial processes, telecommunications, security and electro-medical systems. Master MPS is an on-line double conversion UPS (VFI SS 111- IEC EN 62040-3) with a transformer isolated inverter. The Master MPS range includes three-phase input and single-phase output versions from 10 to 100 kVA, and three-phase input and output versions from 10 to 800 kVA. All versions are provided with 6-pulse thrystor-based rectifier, with or without optional harmonic filters. A 12-pulse thrystor-based rectifier is available on request for the 60 and 80 kVA versions with or without optional harmonic filters.
Flexibility
Master MPS is suitable for a wide range of applications including IT and the most demanding industrial environments. The UPS is suitable for power capacitive loads such as blade servers, from 0.9 leading to 0,8 lagging with a broad range of accessories and options, complex configurations and system architectures can be achieved to guarantee maximum power availability and the option to add new UPS without interruption to existing installations.
For Datacentre, E-Medical, Industry, Transport, Emergency.
Available in 3:1 threephase/threephase 10-200kVA.
Available in 1:1 threephase/singlephase 10-100kVA
RielloUPS All Rights Reserved.
Technical Specification
MODELS | MPM 10 BAT | MPM 15 BAT | MPM 20 BAT | MPM 30 | MPM 40 | MPM 60 | MPM 80 | MPM 100 |
INPUT | ||||||||
Nominal Voltage | 380-400-415 Vac three-phase | |||||||
Voltage tolerance | 400 V +20% /- 25% | |||||||
Frequency | 45-65 Hz | |||||||
Soft start | 0-100% in 120″(selectable) | |||||||
Permitted frequency tolerance | ± 2% (selectable from ±1% to ±5% from front panel) | |||||||
Standard Equipment provided | Back feed protection; separable bypass line | |||||||
BYPASS | ||||||||
Nominal Voltage | 220-230-240 Vac single-phase + N | |||||||
Nominal Frequency | 50 or 60 Hz (selectable) | |||||||
OUTPUT | ||||||||
Nominal power (kVA) | 10 | 15 | 20 | 30 | 40 | 60 | 80 | 100 |
Active power (kW) | 9 | 13.5 | 18 | 27 | 36 | 54 | 72 | 90 |
Number of phases | 1 | |||||||
Nominal Voltage | 220-230-240 Vac single-phase + N(selectable) | |||||||
Static stability | ±1% | |||||||
Dynamic stability | ±5% in 10 ms | |||||||
Voltage distortion | <1% with linear load/ <3% with non-linear load | |||||||
Crest factor | 3:1 lpeack/lrms | |||||||
Frequency stability on battery | 0.05% | |||||||
Frequency | 50 or 60 Hz (selectable) | |||||||
Overload | 110% for 60′; 125% for 10′:150% for 1′ | |||||||
BATTERIES | ||||||||
Type | VRLA AGM / GEL; NiCd; Supercaps; Li-ion;Flywheels | |||||||
Residual ripple voltage | <1% | |||||||
Temperature compensation | -0.5 V x °C | |||||||
Typical charge current | 0.2 x c10 | |||||||
INFO FOR INSTALLATION | ||||||||
Weight without batteries(kg) | 200 | 220 | 230 | 270 | 302 | 440 | 500 | 580 |
Dimensions (WxDxH)(mm) | 555x740x1400 | 800x740x1400 | 800x800x1900 | |||||
Remote signals | dry contacts | |||||||
Remote controls | ESD and bypass | |||||||
Communications | Double RS232 + dry contacts + 2 slots for communication interface | |||||||
Operating Temperature | 0°C/+40°C | |||||||
Relative humidity | <95% non-condensing | |||||||
Colour | Dark grey RAL 7016 | |||||||
Noise level at 1m (ECO Mode) | 60 dBA | 62 dBA | ||||||
IP Rating | IP20 | |||||||
Smart Active efficiency | up to 98% | |||||||
Standards | Directives LV 2006/95/EC-2004/108/EC;Safety IEC EN 62040-1;EMC IEC EN 62040-2;Performance IEC EN 62040-3 | |||||||
Classification in accordance with IEC 62040-3 | (Voltage Frequency Independent) VFI -SS-111 | |||||||
Moving the UPS | transpallet |
Industrial application protection
Master Industrial series UPS provide maximum protection and power quality for any type of load, especially industrial application, such as manufacturing and petrochemical processes, electrical distribution and power plants. Master Industrial is an on-line double conversion UPS (class VFI SS 111 in accordance with IEC EN 62040-3) with input and output isolation transformers.
Industrial Environment
Master Industrial is suited to the most demanding installation environments where there are vibrations, mechanical stresses, dust and in general where operating conditions are unfavourable to products created for the standard UPS market.
Available in 3:1 threephase/singlephase 30-80 kVA DC BUS 220 Vdc.
For Industry, Transport.
Riello UPS All Rights Reserved.
Technical Specification
MODELS | MIM 30 | MIM 40 | MIM 60 | MIM 80 |
INPUT | ||||
Nominal voltage | 380-400-415 Vac three-phase | |||
Voltage tolerance | 400 V± 20% | |||
Frequency | 45-65 Hz | |||
Power factor | >0.93 | |||
Current distortion | <6% | |||
Soft start | 0÷100% in 120″ configurable | |||
Permitted frequency tolerance | ±2% (selectable from ±1% to 5% from front panel) | |||
Standard equipment provided | Back Feed protection;separable bypass line; battery isolation | |||
BATTERIES | ||||
Type | VRLA AGM/ GEL; NiCd | |||
Number of cells | 108/114 | |||
Maximum charging voltage | 274 V | |||
Temperature compensation | -0.5 V x °C | |||
OUTPUT | ||||
Nominal power (kVA) | 30 | 40 | 60 | 80 |
Active power (kW) | 24 | 32 | 48 | 64 |
Nominal voltage | 230 Vac single-phase | |||
Static stability | ±1% | |||
Dynamic stability | ±5% | |||
Voltage distortion | <1% with linear load / <3% with non-linear load | |||
Frequency | 50 or 60 Hz (selectable) | |||
Crest factor | 3:1 lpeack/lrms | |||
Overload | 110% for 60′;125% for 10′;150% for 1′ | |||
Short-circuit current | 3 x l nom. | |||
INFO FOR INSTALLATION | ||||
Weight(kg) | 640 | 650 | 910 | 940 |
Dimensions (WxDxH)(mm) | 800 x 800 x 1900 | 1200 x 800 x940 | ||
Remote signals | dry contacts | |||
Remote controls | ESD and bypass | |||
Communications | Double RS232 + dry contacts + 2 slots for communication interface | |||
Operating temperature | 0°C/ + 40°C | |||
Relative humidity | <95% non-condensing | |||
Colour | Light grey RAL 7035 | |||
Noise level at 1 m (ECO Mode) | 68 ÷ 70 dBA | |||
Ventilation | Redundant fans (front-top) | |||
IP rating | IP20 | |||
Efficiency | up to 94% | |||
Standards | Directives LV 2006/95/EC – 2004/108/EC;Performance IEC EN 62040-3 | |||
Safety IEC EN 62040-1;EMC IEC EN 62040-2 | ||||
Classification in accordance with IEC 62040-3 | (Voltage Frequency Independent) VFI-SS-111 | |||
Moving the UPS | transpellet |
The Incredible levels of quality, reliability and energy savings offered by the Master HP range of UPS have been extended to include a 480 Vac – 60 Hz version, certified as UL, with power ratings from 65 to 250 kVA. IT department managers, facility managers and CTOs are under increasing pressure to achieve zero downtown and to size data centre or industrial installations to be flexible in the face of continuous changes and expansion. As the search for the most reliable and efficient power supply system becomes ever-increasingly critical, Riello UPS has been continuously investing in power solutions to meet demands of a range of our clients; a commitment that resulted in the Master UL range. More than just an innovative and technologically-advanced UPS, it is a leap into the future of three-phase technology.
Available in 3:3 threephase/threephase 65-250 kVA.
For Datacentre, E-Medical, Industry, Transport, Emergency.
Riello UPS All Rights Reserved.
Technical Specification
MODELS | MHT UL 65 | MHT UL 80 | MHT UL 100 | MHT UL 125 | MHT UL 160 | MHT UL 200 | MHT UL 250 |
INPUT | |||||||
Nominal voltage | 480 Vac three-phase + N | ||||||
Frequency | 45-65 Hz | ||||||
Power factor | > 0.99 | ||||||
Harmonic current distortion | <3% THDi | ||||||
Soft start | 0-100% in 30′ (selectable) | ||||||
Frequency tolerance | ±2% (selectable from ±1% to ±5% from front panel) | ||||||
Standard equipment provided | Back Feed protection;separable bypass line | ||||||
BATTERIES | |||||||
Type | VRLA AGM/GEL;NiCd;Li0ion;Supercaps and Flywheel | ||||||
Ripple current | Zero | ||||||
Recharge voltage compensation | -0,5 xV°C | ||||||
OUTPUT | |||||||
Nominal power(kVA) | 65 | 80 | 100 | 125 | 160 | 200 | 250 |
Active power (kW) | 58,5 | 72 | 90 | 112,5 | 144 | 180 | 225 |
Number of phases | 3+N | ||||||
Nominal voltage | 480 Vac three-phase + N | ||||||
Static stability | ±1% | ||||||
Dynamic stability | from ±5% to ±1%% in 20 ms | ||||||
Voltage distortion | <1% with linear load/<3% with non-linear load | ||||||
Crest factor | 3:1 lpeak/lrms | ||||||
Frequency stability on battery | 0,05% | ||||||
Frequency | 60 Hz | ||||||
Overload | 110% for 60′;125% for 10′;150%for1′ | ||||||
INFO FOR INSTALLATION | |||||||
Weight(lbs[kg]) | 1500[680] | 1610[730] | 1742[720] | 1851[840]* | 2138[970]* | 2247[1110]* | |
Weights without manual bypass (lbs[kg]) | – | – | – | 1984[900] | 2534[1145] | 2799[1270] | |
Dimensions (WxDxH)(inches[mm]) | 31,5 x 33,5 75[800 x 500 x 1900] | 55 x 33,5x 75 [1400 x 850 x 1900]* | |||||
Dimensions without manual bypass-(WxDxH)(inches[mm]) | – | 39 x 33,5 x75[1000 x 850 x1900] | |||||
Remote controls | ESD and bypass (configurable) | ||||||
Communications | Double RS232 + dry contacts + 2 slots for communication interface | ||||||
Operating temperature | 0°C/+40°C | ||||||
Relative humidity | <95% non-condensing | ||||||
Color | Dark Grey RAL 7016 | ||||||
Noise level at 1m (ECO Mode) | 65 dBA | 68dBA | |||||
IP rating | IP20 | ||||||
Smart Active efficiency | Up to 98,5% | ||||||
Standards | UL Standard 1778:2nd edition from 65 to 125 kVA, 4th edition from 160 to 250 kVA; | ||||||
National Electrical Code (NFPA-70);NEMA PE-1;CUL – CSA C22.2;ASME; | |||||||
ASA-C-39.1-1984;FCC section 15 subsection J class A; NEC; OSHA; IEEE 587;ANSI C 62.41-198;ISO 9000 | |||||||
Lightning and Power Equipment, Auxiliary (OUST) | |||||||
Classification in accordance with IEC 62040-3 | Voltage Frequency Independent VFI-SS-111 | ||||||
Moving the UPS | transpallent |
*with Top Cable Entry
The Master HP series from 100 to 600 kVA is the Riello UPS solution for installations requiring high energy efficiency and maximum power availability. Master HP Series provides maximum protection and power quality for data centres and industrial loads. The UPS has an IGBT-based rectifier, DSP (Digital Signal Processors) technology and provides true on-line, double conversion power protection, (VFI SS11-Voltage and Frequency Independent in accordance with IEC EN 62040-3).
Maximised Cost Savings
The Master HP has the ability to monitor the mains input quality and to select the best operating mode based on the interference present (Smart Active Mode) or circular redundancy (Parallel Energy Saving Mode, which allows the UPS to regulate available capacity based on the immediate demands of the load, automatically switching to standby in the event of the excess capacity), the Master HP also offers high levels of efficiency for partial loads, resulting in reduced operating costs.
For Datacentre, E-Medical, Industry, Transport, Emergency.
Available in 3:3 threephase/threephase 100-600kVA.
Riello UPS All Rights Reserved.
Technical Specification
MODELS | MHT 100 | MHT 120 | MHT 160 | MHT 200 | MHT 250 | MHT 300 | MHT 400 | MHT 500 | MHT 600 |
INPUT | |||||||||
Nominal Voltage | 380-400-415 Vac three-phase | ||||||||
Frequency | 45-65 Hz | ||||||||
Power factor | >0.99 | ||||||||
Harmonic current distortion | <3% THDi | ||||||||
Soft start | 0-100% in 120″ (selectable) | ||||||||
Frequency tolerance | ±2%(selectable from±1% to 5% from front panel) | ||||||||
Standard equipment provided | Back feed protection;separable bypass line | ||||||||
BYPASS | |||||||||
Nominal voltage | 360-400-420 Vac three-phase + N | ||||||||
Nominal frequency | 50 or 60 Hz (Selectable) | ||||||||
OUTPUT | |||||||||
Nominal power (kVA) | 100 | 120 | 160 | 200 | 250 | 300 | 400 | 500 | 600 |
Active power (kW) | 90 | 108 | 144 | 180 | 225 | 270 | 360 | 450 | 540 |
Number of phases | 3 + N | ||||||||
Nominal voltage | 380-400-415 Vac three-phase + N(selectable) | ||||||||
Static stability | ±1% | ||||||||
Dynamic stability | ± 5% in 10ms | ||||||||
Voltage distortion | <1% with linear load/<3% with non-linear load | ||||||||
Crest factor | 3:1 lpeack/lrms | ||||||||
Frequency stability on battery | 0,05% | ||||||||
Frequency | 50 or 60 Hz (selectable) | ||||||||
Overload | 110% for 60′; 125% for 10′; 150% for 1′ | ||||||||
BATTERIES | |||||||||
Type | VRLA AGM/ GEL; NiCd;Supercaps; Li-ion; Flywheels | ||||||||
Ripple current | Zero | ||||||||
Recharge voltage compensation | -0.5 V x°C | ||||||||
INFO FOR INSTALLATIONS | |||||||||
Weight (kg) | 656 | 700 | 800 | 910 | 1000 | 1400 | 1700 | 2100 | 2400 |
Dimensions (WxDxH)(mm) | 800 x 850 x 1900 | 1000x 850 x 1900 | 1500 x 1000×1900 | 2100x1000x1900 | |||||
Remote signals | dry contacts (configurable) | ||||||||
Remote controls | ESD and bypass (configurable) | ||||||||
Communications | Double RS232 + dry contacts + 2 slots for communications interface | ||||||||
Operating temperature | 0°C/ +40°C | ||||||||
Relative humidity | <90% non-condensing | ||||||||
Colour | Dark grey RAL 7016 | ||||||||
Noise level at 1 m | 63-68dBA | 70-72 dBA | |||||||
IP Rating | IP20(others on request) | ||||||||
Smart Active efficiency | up to 98.5% | ||||||||
Standards | Safety: EN 62040-1-1(Directive 2006/95/EC); EMC:EN 62040-2(Directive 2004/108/EC) | ||||||||
Classification in accordance with IEC 62040-3 | (Voltage Frequency Independent) VFI-SS-111 | ||||||||
Moving the UPS | transpallet |
HE-High Efficiency
Master HE series is available from 100 to 800 kVA. The UPS features a new on-line double-conversion technology utilizing IGBT and DSP (Digital Signal Processor) control to provide maximum protection, power quality and green energy for any type of application including datacenters, disaster recover sites, telecoms rooms, industrial processes and security applications. High efficiency stands for higher active power available if compared with legacy UPS thanks to output unitary power factor (up to +25% if compared unity with the same UPS at p.f. 0,8). Nominal power is granted with no downgrading independently from operating temperature in the range 10÷40°C. Furthermore, control circuits and specifically designed firmware grant outstanding online double conversion efficiency up to 95,5%, comparable with the best transformerless UPS available on the UPS market.
Maximized Cost Savings
The build specifications offered by the Master HE range and the exceptional level of efficiency help to absorb the TCO, from the installation stage to the daily operation, reducing power costs for the UPS, air conditioning system and installation area costs thanks to reduced size and weight.
For Datacentre, E-Medical, Industry, Transport, Emergency.
Available in 3:3 threephase/threepase 100-800 kVA.
RielloUPS All Rights Reserved.
Technical Specification
Models | MHE 100 | MHE 120 | MHE 160 | MHE 200 | MHE 250 | MHE 300 | MHE 400 | MHE 500 | MHE 600 | MHE 800 |
INPUT | ||||||||||
Nominal Voltage | 380 – 400 – 415 Vac 3-phase | |||||||||
Frequency | 45÷65 Hz | |||||||||
Power factor | >0.99 | |||||||||
Harmonic current distortion | <3% THDi | |||||||||
Soft start | 0÷100% in 120″(selectable) | |||||||||
Frequency tolerance | ±2%(selectable from ±1% to ±5% front panel) | |||||||||
Standard equipment | Back Feed protection;separable bypass line | |||||||||
BYPASS | ||||||||||
Nominal voltage | 360-400-420 Vac 3-phase + N | |||||||||
Frequency | 50 or 60 Hz selectable | |||||||||
OUTPUT | ||||||||||
Nominal Power (kVA) | 100 | 120 | 160 | 200 | 250 | 300 | 400 | 500 | 600 | 800 |
Active Power (kW) | 100 | 120 | 160 | 200 | 250 | 300 | 400 | 500 | 600 | 800 |
Number of phases | 3 + N | |||||||||
Nominal voltage | 380-400-415 Vac 3-phase + N(selectable) | |||||||||
Static stability | ±1% | |||||||||
Dynamic stability | ±5% in 10 ms | |||||||||
Voltage distortion | <1% with linear load/ <3% with non-linear load | |||||||||
Crest factor (lpeak/lrms) | 3:1 | |||||||||
Frequency stability on battery | 0.05% | |||||||||
Frequency | 50 or 60 Hz (selectable) | |||||||||
Overload | 110% for 60′; 125% for 10′;150% for 1′ | |||||||||
BATTERIES | ||||||||||
Type | VRLA AGM/ GEL; NiCd;Supercaps;Li-ion; Flywheels | |||||||||
Ripple current | Zero | |||||||||
Charge voltage compensation | 0.5 V x °C | |||||||||
INFO FOR INSTALLATION | ||||||||||
Weight(kg) | 730 | 785 | 865 | 990 | 1090 | 1520 | 1670 | 2500 | 2830 | 3950 |
Dimensions (WxDxH)(mm) | 800x850x1900 | 1000x850x1900 | 1500x1000x1900 | 2100x1000x1900 | 3200x1000x1900 | |||||
Remote signals | volt-free contacts (configurable) | |||||||||
Remote controls | ESD and bypass(configurable) | |||||||||
Communication | Double RS232+remote contacts +2 slots for communications interface | |||||||||
Ambient temperature | 0°C/±40°C | |||||||||
Relative humidity | <90% non-condensing | |||||||||
Colour | Dark grey RAL 7016 | |||||||||
Noise level(@1 m) | 63÷68 dBA | 70÷72 dBA | ||||||||
Protection level | IP20 (others upon request) | |||||||||
Smart Active Efficiency | >99% | |||||||||
Double Conversion Efficiency | up to 95,5% | |||||||||
Regulations | Safety:EN 62040-1(directive 2006/95/EC);EMC:EN 62040-2(directive 2004/108/EC) | |||||||||
Classification accoring to IEC 62040-3 | (Voltage Frequency Independent) VFI-SS-111 |
Master FC400 series static frequency converters are available from 30 to 120 kVA, with 50 or 60 Hz input and 400 Hz output. The result of extensive experience acquired in the UPS Industry, the Master FC400 series is distinguished by the use of technologically advanced components and for excellent reliability, ease of maintenance and ease of operation. The Master FC400 series uses double conversion technology (VFI SS 111 voltage and frequency independent compliant with IEC EN 62040-3), with an integrated output transformer to ensure the galvanic isolation of the load from mains disturbances under all conditions. The Output voltage is 208 Vac three-phase (adjustable 200÷215 Vac). Thanks to high frequency IGBT technology and digital control, Master FC400 frequency converters are ideal for airport, military and naval application.
Available in 3:3 threephase/threephase 30-125 kVA.
For airport, military, and naval.
Riello UPS All Rights Reserved.
Technical Specification
MODELS | MFC 30 | MFC60 | MFC80 | MFC100 | MFC125 |
INPUT | |||||
Nominal voltage | 380-400-415 Vac Three-phase | ||||
Voltage tolerance | 400 V ± 20% | ||||
Frequency | 45-65 Hz | ||||
Current distortion | <5% C (HC Version) | ||||
Soft start | 0-100% in 120″ configurable | ||||
OUTPUT | |||||
Nominal power (kVA) | 30 | 60 | 80 | 100 | 125 |
Active power (kW) | 24 | 48 | 64 | 80 | 100 |
Nominal voltage | 208 Vac three-phase + N | ||||
Static stability | ±1% | ||||
Dynamic stability | ±5% | ||||
Voltage distortion | <3% with linear load/ <4% with non-linear load | ||||
Frequency | 400 Hz | ||||
Crest factor | 3/1 | ||||
Overload | 110% for 60′;125% for 10′; 150% for 1′ | ||||
INFO FOR INSTALLATION | |||||
Weight(kg) | 330 | 480 | 500 | 530 | 590 |
Dimensions (WxDxH)(mm) | 555 x 740 x1400 | 800 x 800 x 1900 | |||
Remote signals | dry contacts | ||||
Remote controls | ESD and ON/OFF | ||||
Communications | Double RS232 + dry contacts + 2 slots for communication interface | ||||
Operating temperature | 0°C/ +40°C(50°C @75% load) | ||||
Relative humidity | <95% non-condensing | ||||
Colour | Light grey RAL 7036 | ||||
Noise level at 1 m (ECO Mode) | 62 dBA | 65 dBA | 68 dBA | 70 dBA | 72 dBA |
IP rating | IP20 (others on request) | ||||
Efficiency | up to 92% | ||||
Standards | Directives LV 2006/95/EC-2004/108/EC; Safety IEC EN 62040-1; | ||||
EMC IEC EN 602040-2; Performances IEC EN 62040-3 | |||||
Classification in accordance with IEC 62040-3 | (Voltage Frequency Independent) VFI -SS – 111 | ||||
Moving the UPS | transpallet |